CAT. III 600V
60MΩ
60mF
800A
1000℃, 1832℉
200g
185*65*32mm
10MHz
6000 digits
600V
CM-2018
CM-2018 AC/DC 3 5/6 Digital Clamp Multimeter
Features:
1. Clamp opens 28mm
2. AC DC T-RMS, NCV, LPF(VFC), LoZ V function
3. Clamp light, Backlight, Flash light
4. Max. 6000 digits large LCD display
5. CE standard design, improves the safety of the test
6. Full function protection, strong anti-interferential performance
7. Duty cycle test, REL test, data hold, Auto power off function
Technical Data:
Basic function | Range | Accuracy |
DCV | 600mV/6V/60V/600V | ±(0.5%+5) |
LoZ 0V~600V | ±(2.0%+10) | |
ACV | 6V/60V/600V | ±(0.8%+5) |
LPF 0V ~ 600V | ±(4.0%+5) | |
LoZ 0V ~ 600V | ±(2.0%+10) | |
DCA | 60A/600A/800A | ±(1.5%+5) |
ACA | 60A/600A/800A | ±(1.5%+5) |
Resistance | 600Ω/6KΩ/60KΩ/600KΩ/6MΩ/60MΩ | ±(0.8%+1) |
Capacitance | 6nF/60nF/600nF/6uF/60uF/600uF/6MF/60MF | ±(2.5%+5) |
Frequency | 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz | ±(0.5%+4) |
Temperature | (-40 to 1000 )℃, (-40 to 1832 ) ℉ | ±(1.0%+5) |
Special Function:
Model | CM-2018 |
NCV test | √ (clamp & red test lead detecting) |
True RMS test | √ |
LPF (VFC) function | √ |
LoZ function | √ |
Low battery indicator | Approx. less than 2.6 V |
Data hold function | √ |
Auto power off | About 15 minutes |
Diode test | √ |
Continuity test | Less than 50Ω |
Duty-cycle test | √ |
REL test | √ |
Clamp light function | √ |
Backlight display | √ |
Orange backlight display for high volt | √ |
Input impedance | 10MΩ |
Sampling rate | 3 times/s |
AC frequency response | 40-2kHz |
Operation method | Auto or manual range |
Max display | 6000 |
Clamp opens | 28mm |
Battery | 3V (2*AAA battery) |
Power consumption | Quiescent current approx. 2mA |
General Characteristic:
Meter color | Orange and Black |
Meter weight | About 200g (including battery) |
Meter size | 185*65*32mm |
Standard accessory | Test leads, battery, manual, temperature probe, carrying bag |
Standard packing | Gift box |
Carton size | 41.5*28*46.5CM |
Standard QTY per carton | 40pcs |
G.W per carton | 15kg |
Note: for the NCV detecting function, this clamp meter is not only can detect the NCV by clamp, but also can be directly touched by the red stylus probe to detect cable that could not be reached by the clamp.