0.3%-100%(4KHz)
Short circuit/ Over load/ Over temperature/Over voltage
Suitable for LED lighting and moving sign applications
100-277VAC
1200mA Min load is 24V 1600mA Min load is 12V
Cooling by free air convection
Constant Current
Built-in active PFC function
Up to 89%
IP66(EU); for dry, damp and wet locations(US)
Model | SMT-DI100W160-DP2A-T | SMT-DI100W210-DP2A-T | |
Certificate | UL/FCC/CE /ClassP/TYPE HL/SELV/ RoHS / Reach/ENEC/ICES/UKCA | ||
Output | Rated current | 160mA-1600mA | 210mA-2100mA |
DC Voltage | 24-93VDC | 12-54VDC | |
Rated power | 100Wmax | ||
Current Tolerance | Output current ± 30mA | ||
Line Regulation | <0.1% | ||
Load Regulation | <0.1% | ||
Voltage Range | 100-277VAC | ||
Input | Frequency Range | 47 - 63Hz | |
Power Factor (Typ.) | >0.99@120VAC 60Hz >0.98@230VAC 50HZ >0.97@277VAC 60HZ | ||
No load power (Max) | <2W | ||
Standby power (Max) | <0.5W | ||
THD(Typ.) @ full load | <5.5%@120VAC <9.5%@230VAC <10.5%@277VAC | ||
Efficiency @ full load | >89.8%@120VAC 60Hz >91.7%@230VAC 50HZ >91.3%@277VAC 60HZ | >88.8%@120VAC 60Hz >90.7%@230VAC 50HZ >90.7%@277VAC 60HZ | |
AC Current (Max.) | <1.28A | ||
Inrush Current (Typ.) | 23.2A,398us @50%Ipeak 120VAC 48.8A,171us @50%Ipeak 230VAC 58.7A,404us @50%Ipeak 277VAC | 24.8A,412us @50%Ipeak 120VAC 56.8A,120us @50%Ipeak 230VAC 68.4A,580us @50%Ipeak 277VAC | |
Leakage current | <0.5mA | ||
Protection | Short Circuit | Hiccup mode, recovers automatically after fault condition is removed | |
Over voltage | Hiccup or constant power mode, reboots automatically after fault condition is removed | ||
Over temperature | Ambient temperature over 55℃±5℃ to reduce output to 50%; The ambient temperature drops to 45℃ ±5℃and automatically recovers. Ambient temperature over 75℃±5℃ to reduce output to 0%; The ambient temperature drops to 45℃ ±5℃and automatically recovers. | ||
Environment | Working TEMP | -40~+50℃ (see below derating curve) | |
Working Humidity | 20 -90%RH non-condensing | ||
Storage TEM.,Humidity | -40 - +80℃,10 - 95% RH | ||
TEMP.coefficient | ±0.03%/℃(0 - 50℃) | ||
Vibration | 10~500Hz, 5G 12min./1 cycle, period for 72min. each along X,Y,Z axes | ||
Safety & EMC | Safety standards | EN61347-1 EN61347-2-13(EU) & UL8750 (US) | |
Withstand voltage | I/P-O/P:3.75KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC (EU) I/P-O/P:1.8KVAC I/P-FG:1.8KVAC O/P-FG:1.8KVAC (US) | ||
Strobe test standard | IEEE 1789 Flicker free | ||
Surge Immunity Test | AC Power Line:Differential Mode 2 kV, Common Mode 4 kV | ||
Isolation resistance | I/P-O/P:100MΩ / 500VDC / 25℃ / 70%RH | ||
EMC Emission | EN55015 EN61000-3-2,3(EU) & FCC Part15 Subpart B; ANSI C63.4:2014(US) | ||
Others | Net Weight | 600g | |
Dimension | 365.8*38.5*23.6mm (L*W*H) | ||
Packing | 55*31*387 30pcs /CTN | ||
Notes | 1. All parameters NOT specially mentioned are measured at rated load and 25℃of ambient temperature. | ||
2. To extend the driver's using life, please reduce the loading at lower input voltage . | |||
3. LED driver Meets the harmonic emissions requirements of ANSI C82.77-10. |