SMT-24096-VT-P
SMARTS
0-100% Dimming depth 0.1%
100-277VAC
Constant Voltage
Short circuit/ over load/ over temperature
7 Years Warranty
Phase dimming: work with forward phase /leading edge, MLV and Reverse phase /trailing edge, ELV, TRIAC dimmers
Model | SMT-24096-VT-P | SMT-48096-VT-P | |
Certificate | UL / cUL / FCC / Class P / Class 2/Type HL/ICES-005 | ||
Output | DC Voltage | 24V | 48V |
Voltage Tolerance | ±2% | ±2% | |
Voltage Regulation | ≤0.5% | ≤0.5% | |
Load Regulation | ≤0.5% | ≤0.5% | |
Rated current | ≤2% | ≤2% | |
Rated power | 96W | ||
Voltage Ripple | 296mv | 176mv | |
Overshoot voltage | <3%(full load) | <3%(full load) | |
Output mode selection | When the blue&white wire and the yellow&gray wire at the output terminal are short-circuited, it indicates the Pulse-Width Modulation (PWM) mode. When they are disconnected, it indicates the Voltage Regulation (VR) mode of direct current voltage modulation. | ||
Switching the output mode requires the power to be cut off for 3 seconds and then powered on again for the mode switching to take effect. | |||
Input | Voltage Range | 100-277VAC | |
Frequency Range | 47 - 63Hz | ||
Power Factor (Typ.) @ full load | >0.98@120VAC >0.97@277VAC | >0.98@120VAC >0.97@277VAC | |
THD(Typ. ) @ full load | <15%@120V <15%@277V | ||
Efficiency(Typ.) @ full load | ≥88%@120VAC ≥91.5%@277VAC | ≥87%@120VAC ≥90.5%@277VAC | |
AC Current (Max.) | ≤1.0A @120VAC ≤0.43A@277VAC | ||
Standby power | ≤0.5W | ||
Inrush Current (Typ.) | 51A,208us@50%Ipeak 120VAC 118A,452us@50%Ipeak 277VAC | ||
Leakage current | <0.5mA | ||
Protection | Short Circuit | Hiccup mode, can be automatically restored after abnormal removal | |
Over Load | ≥120%,Constant - Current Mode, automatic recovery after exception | ||
Over temperature | When the ambient temperature exceeds 55℃ ±5℃, the output is turned off | ||
Environment | Working TEMP. | -40~+40℃ (see below derating curve) | |
Working Humidity | 20 - 95%RH non-condensing | ||
Storage TEM.,Humidity | -40 - +80℃,10 - 95% RH non-condensing | ||
TEMP.coefficient | ±0.03%/℃(0 - 50℃) | ||
Vibration | 10 ~ 500Hz, 5G 12 minutes/cycle, X Y Z axis 72 minutes each | ||
Safety & EMC | Safety standards | UL8750 CAN/CSA-C22.2 No.250.13 | |
Withstand voltage | I/P-O/P:1.88KVac;I/P-FG::1.88KVac;O/P-FG:0.5KVac | ||
Isolation resistance | I/P-O/P:100MΩ / 500VDC / 25℃ / 70% RH | ||
Surge Immunity Test | AC Power Line:Differential Mode 2KV,Common Mode 4KV | ||
EMC Immunity | FCC/ICES do not request this test | ||
EMC Emission | FCC Part15 Subpart B;ANSI C63.4:2017;ICES-005 Issue 5 | ||
Others | Net Weight | 0.56KG | |
Dimension | 188*61.4*25.5mm(L*W*H) | ||
Packing | 415*230*170mm 20 pcs / CTN | ||
Notes | 1. All parameters NOT specially mentioned are measured at 120VAC input, rated load and 25℃of ambient temperature. | ||
2. Tolerance: includes set up tolerance and load regulation . | |||
3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. | |||
4. Default states:The output mode is VR output by default. The dimming curve is a gamma2.2 curve. | |||
5. Regarding LED driver load types where the driver meets the harmonic emissions requirements of ANSI C82.77-10. |