Short circuit/ over load/ over temperature
Constant Voltage
0-100% Dimming depth 0.1%
7 Years Warranty
100-277VAC
SMARTS
SMT-12060-VT-P
Phase dimming: work with forward phase /leading edge, MLV and Reverse phase /trailing edge, ELV, TRIAC dimmers
Model | SMT-12060-VT-P | SMT-24060-VT-P | SMT-48060-VT-P | |
Certificate | UL / cUL / FCC / Class P / Type HL / Class 2 | |||
Output | DC Voltage | 12V | 24V | 48V |
Voltage Tolerance | ±5% | ±3% | ±2% | |
Voltage Regulation | ≤0.5% | ≤0.5% | ≤0.5% | |
Load Regulation | ≤2% | ≤1% | ≤1% | |
Rated current | 5A | 2.5A | 1.25A | |
Rated power | 60W | |||
Voltage Ripple | 500mVp-p | 450mVp-p | 450mVp-p | |
Overshoot voltage | <7%(full load) | <5%(full load) | <5%(full load) | |
Output mode selection | When the purple wire and the pink wire at the output terminal are short-circuited, it indicates the Pulse-Width Modulation (PWM) mode. When they are disconnected, it indicates the Voltage Regulation (VR) mode of direct current voltage modulation. | |||
Switching the output mode requires the power to be cut off for 3 seconds and then powered on again for the mode switching to take effect. | ||||
Input | Voltage Range | 100-277VAC | ||
Frequency Range | 47 - 63Hz | |||
Power Factor (Typ.) @ full load | >0.98@120VAC >0.97@277VAC | >0.98@120VAC >0.97@277VAC | >0.98@120VAC >0.97@277VAC | |
THD(Typ. ) @ full load | <15%@120V <15%@277V | |||
Efficiency(Typ.) @ full load | ≥83%@120VAC ≥84%@277VAC | ≥83%@120VAC ≥85%@277VAC | ≥84%@120VAC ≥86%@277VAC | |
AC Current (Max.) | ≤0.75A @120VAC ≤0.3A@277VAC | |||
Standby power | ≤0.5W | |||
Inrush Current (Typ.) | 31.6A,152us@50%Ipeak 120VAC 76.8A,156us@50%Ipeak 277VAC | |||
Leakage current | <0.5mA | |||
Protection | Short Circuit | Hiccup mode, can be automatically restored after abnormal removal | ||
Over Load | ≥120%,Constant - Current Mode, automatic recovery after exception | |||
Over temperature | When the ambient temperature exceeds 55℃ ±5℃, the output is turned off | |||
Environment | Working TEMP. | -40~+40℃ (see below derating curve) | ||
Working Humidity | 20 - 95%RH non-condensing | |||
Storage TEM.,Humidity | -40 - +80℃,10 - 95% RH non-condensing | |||
TEMP.coefficient | ±0.03%/℃(0 - 50℃) | |||
Vibration | 10 ~ 500Hz, 5G 12 minutes/cycle, X Y Z axis 72 minutes each | |||
Safety & EMC | Safety standards | UL8750 CAN/CSA-C22.2 No.250.13 | ||
Withstand voltage | I/P-O/P:1.88KVac;I/P-FG::1.88KVac;O/P-FG:0.5KVac | |||
Isolation resistance | I/P-O/P:100MΩ / 500VDC / 25℃ / 70% RH | |||
Surge Immunity Test | AC Power Line:Differential Mode 2KV,Common Mode 4KV | |||
EMC Immunity | FCC/ICES do not request this test | |||
EMC Emission | FCC Part15 Subpart B;ANSI C63.4:2017;ICES-005 Issue 5 | |||
Others | Net Weight | 0.5KG | ||
Dimension | 188*61.4*25.5mm(L*W*H) | |||
Packing | 415*230*170mm 20 pcs / CTN | |||
Notes | 1. All parameters NOT specially mentioned are measured at 120VAC input, rated load and 25℃of ambient temperature. | |||
2. Tolerance: includes set up tolerance and load regulation . | ||||
3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. | ||||
4. Default states:The output mode is PWM output by default. The dimming curve is a gamma2.2 curve. | ||||
5. Regarding LED driver load types where the driver meets the harmonic emissions requirements of ANSI C82.77-10. |