Ultra Thin LED Power Supply | 灯饰 | 照明配件及零件
中国内地
展位编号: 5C-A12 | LED照明 |
产品规格
型号编号

KY-360-12-LR

应用

LED Strip Light

尺寸

215*115*30mm

材料

Aluminum

产品简介
Switching Power Supply








Product features:


•  Protection function: short circuit, over current and overload;
•  Reasonable circuit design layout, high conversion efficiency, low temperature rise;


•  100% full load aging test;


•  Small output ripple, high working efficiency, small size and light weight;


•  Every product has an impact test;
specification




Type12V 360W24V 360W
OutputDC voltage12V24V
Rated current30A15A
Current range0~30A0~15A
rated power360W360W
Ripple and noise120mV240mV
Voltage adjustment11.2~12.823.2~24.8
Range  ±2%±2%
Voltage accuracy±0.5%±0.5%
Linear adjustment rate±1%±1%
Start time≤1000ms/230VAC(full loaded)    
Retention time(Typ.)30ms/230VAC(full loaded)
InputVoltage range(V)180-240VAC
Frequency range(Hz)47~63Hz
Efficiency(Typ.)83%85%
AC current(Typ.)0.58A 230VAC       
Inrush current(Typ.)cold start time <50A/230VAC
Leakage current<0.75mA/240VAC
Protection featuresShort circuit protectionProtection method: hiccup mode,automatic recovery after abnormal removal.
Overload protection110%~150% of rated output power Protection mode:hiccup mode,automatic recovery after abnormal removal.
ConditionWorking temperature(℃) -10℃ - +45℃ 
Working temperature(℃)20% - 90%RH,No condensation
Storage temperature、humidity -20℃ - +85℃  ,10% - 95%RH,No condensation
Temperature coefficient±0.3‰( 0 - 50℃  )
Vibration resistance10-500Hz,2g 10min/cycle,X、Y、Z axes each 60 minutes.
Safety standardWithstand voltage(VAC)I/P-O/P:1.5KVAC,I/P-FG:0.5KVAC,OP-FG:0.5KVAC  60S
Safety standardReference EN/UL60950-1,GB4943 Standard design
Insulation resistanceI/P-O/P,I/P-FG,O/P-FG: 100M Ohm/500VDC/25℃
Note1. All unspecified parameters are measured at 230VAC voltage input, rated load and 25 degree.
2.Ripple and noise voltage:It is measured when a 12-inch twisted pair is used in a 20MHz bandwidth, and 0.1μand 47μ capacitors are connected in parallel at the terminal.
3.Accuracy:Including setting error, Linear adjustment rate and load adjustment rate.
4.Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5.Load adjustment rate measurement method:From 0% to 100% rated load.
6.The startup time is measured under the cold start state,and the rapid and frequent switching on and off may increase the startup time.
7.When the operating altitude is higher than 2000 meters(6500ft),the operating ring temperature needs to be lowered by 5 degree/1000 meters.
Packageproduct size215*115*30(mm)(L*W*H)  
 
 
Carton Quantity30PCS

 
Carton Size51.5*35.8*22cm

 
 

 



 
 



 
     3 
生产所需时间