Cooling by free air convection
Short circuit / Over load / Over temperature
0-100%
Constant Voltage
7 years warranty
Built-in active PFC function
Up to 91%
100-277VAC
12V&24V: Full aluminum protection housing, for dry, damp & wet locations. 48V: Full aluminum protection housing, for dry and damp locations.
| Model | SMT-24096-2C-TWVD-A | SMT-48096-2C-TWVD-A | |
| Certificate | UL / cUL / FCC / Class P / Class 2 / TYPE HL / SELV / ROHS / REACH | ||
| Output | Rated Voltage | 24V | 48V |
| DC Voltage | 24-26V adjust by NFC | 48-50V adjust by NFC | |
| Voltage Tolerance | ±0.5V | ±0.5V | |
| Voltage Regulation | ≤0.5% | ≤0.5% | |
| Load Regulation | ≤1% | ≤1% | |
| Rated current | 4A | 2A | |
| Rated power | 96W | ||
| Input | Voltage Range | 100-277VAC | |
| Frequency Range | 50 / 60Hz | ||
| Power Factor (Typ.) @ full load | >0.95 | ||
| THD(Typ. ) @ full load | ≤15% | ||
| Efficiency(Typ.) @ full load | 88%@120VAC 89%@230VAC 90%@277VAC | 88%@120VAC 89%@230VAC 90%@277VAC | |
| AC Current (Max.) | 1.2A | ||
| Inrush Current (Typ.) | 28A, 320us @50%120VAC 90A, 76us @50%230VAC 58A, 260us @50%277VAC | ||
| Leakage current | <0.5mA | ||
| Protection | Short Circuit | Hiccup mode, recovers automatically after fault condition is removed. | |
| Over Load | 105%~120% Hiccup mode, recovers automatically after fault condition is removed. | ||
| Over temperature | Shell surface temp.100℃±10℃ shut down o/p voltage, automatically recover after cooling. | ||
| Environment | Working TEMP. | -40~+60℃ (see below derating curve) | |
| Working Humidity | 20 -95%RH non-condensing | ||
| Storage TEM.,Humidity | -40 - +80℃,10 - 95% RH non-condensing | ||
| TEMP.coefficient | ±0.03%/℃(0 - 50℃) | ||
| Vibration | 10~500Hz, 5G 12min./1 cycle, period for 72 min. each along X,Y,Z axes | ||
| Safety & EMC | Safety standards | UL8750; CAN/CSA-C22.2 No. 250.13 | |
| Withstand voltage | I/P-O/P:1.88KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC | ||
| Isolation resistance | I/P-O/P:100MΩ / 500VDC / 25℃ / 70%RH | ||
| EMC Immunity | FCC/ICES do not request this test. | ||
| EMC Emission | FCC CFR Title 47 Part 15 Subpart B:2020; ICES-005 Issue 5 | ||
| Others | Net Weight | 0.83KG | |
| Dimension | 232*78*25.1mm(L*W*H) | ||
| Packing | 300*280*215mm 20pcs/CTN | ||
| Notes | 1. All parameters NOT specially mentioned are measured at 120VAC input,rated load and 25℃ of ambient temperature. | ||
| 2. Under low input voltage, derating output is required to ensure a long life. | |||