Full plastic protection housing, for dry & damp locations .
Cooling by free air convection
0.3%-100%
Constant Current
Built-in active PFC function
0-10V dimming, 1-10V dimming, flicker free
Up to 81%
100-277VAC
0-10V signal-end isolation,Driver parameters can be adjusted by NFC APP.
Short circuit/ Over load/ Over temperature/Over voltage
Model | SMT-DI020W070-CDP-T | |
Certificate | UL/FCC/CE /ClassP/Class2/TYPE HL/SELV/ RoHS / Reach/ENEC/ICES/UKCA | |
Output | On-load voltage range | 12-54V |
Output Current Setting(loset) | 70-700mA | |
Range | ||
Output Current Setting Range | 370-700mA | |
with Constant Power | ||
Rated power | 20W(Max) | |
No Load Output Voltage | 60V(Max) | |
Current Tolerance | 700mA±5% | |
Total Output Current Ripple | 20mA(Imax) | |
Startup Overshoot Current | 9%(Max) | |
Line Regulation | <0.5% | |
Load Regulation | <0.5% | |
Input | Voltage Range | 100-277VAC |
Frequency Range | 50/60Hz | |
Standby Power | ≤0.5W | |
Power Factor (Typ.) @ full load | 0.99@120VAC 0.97@230VAC 0.93@277VAC | |
THD(Typ. ) @ full load | <10%@100-277VAC | |
Efficiency(Typ.) @ full load | 82%@120VAC 82%@230VAC 82%@277VAC | |
AC Current (Max.) | <0.3A@120VAC <0.22A@230VAC <0.15A@277VAC | |
Standby power | ≤0.5W | |
Inrush Current (Typ.) | 17.5A, 50%, 29.1us @120VAC; 33.6A, 50% 864us @277VAC 40.4A, 50% 26us @277VAC | |
Leakage current | <0.5mA | |
Protection | Short Circuit | Constant current mode, recovers automatically after fault condition is removed |
Over Load | ≥110% Constant current mode,recovers automatically after fault condition is removed | |
Over temperature | Ambient temperature over 50℃±5℃ to reduce output to 50%; | |
The ambient temperature drops to 40℃ ±5℃and automatically recovers. | ||
Ambient temperature over 60℃±5℃ to reduce output to 0%; | ||
The ambient temperature drops to 40℃ ±5℃and automatically recovers. | ||
Environment | Working TEMP. | -40~+45℃ (see below derating curve) |
Working Humidity | 20 - 95%RH non-condensing | |
Storage TEM.,Humidity | -40 - +80℃,10 - 95% RH non-condensing | |
TEMP.coefficient | ±0.03%/℃(0 - 50℃) | |
Vibration | 10~500Hz, 2G 12min./1 cycle, period for 72min. each along X,Y,Z axes | |
Safety & EMC | Safety standards | UL8750;EN61347-1 |
Withstand voltage | I/P-O/P:1.88KVAC(MAX 3.75KVAC) | |
Isolation resistance | I/P-O/P: 100MΩ/ 500VDC/ 25℃/ 70% RH | |
EMC Immunity | IEC/EN61000-4-2,3,4,5,6,8,11; EN/EN61547 | |
EMC Emission | EN55015 EN61000-3-2,3 FCC Part15 Subpart B;ANSI C63.4:2014 | |
Surge Immunity Test | AC Power Line:Differential Mode 2 kV, | |
Others | Net Weight | 215g |
Dimension | 251.9*31*22.5mm(L*W*H) | |
Packing | 290*225*215mm 50pcs /CTN | |
Notes | 1. All parameters NOT specially mentioned are measured at 120VAC input, rated load and 25℃of ambient temperature. | |
2. Default states: | ||
Output Current Setting is Maximum value. | ||
The dimming curve is a logarithmic curve. | ||
3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation agai | ||
4. To extend the driver's using life , please reduce the loading at lower input voltage . | ||
5. Dimming electrical circuit: | ||
Notice: This control circuit is isolated,but didn't evaluate Class 2. | ||
Please refer to the installation manual to connect the dimmer. | ||
CAUTlON: More than one power supply present. | ||
ATTENTION: presence de plusieurs alimentations électriques. |